Journal Information
Journal ID (publisher-id): BM
Journal ID (nlm-ta): Biochem Med (Zagreb)
Title: Biochemia Medica
Abbreviated Title: Biochem. Med. (Zagreb)
ISSN (print): 1330-0962
ISSN (electronic): 1846-7482
Publisher: Croatian Society of Medical Biochemistry and Laboratory Medicine
Article Information
Copyright statement: ©Croatian Society of Medical Biochemistry and Laboratory Medicine.
Copyright: 2021, Croatian Society of Medical Biochemistry
License (open-access):
This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Date received: 17 December 2020
Date accepted: 25 February 2021
Publication date (electronic): 15 April 2021
Publication date (print): 15 June 2021
Volume: 31
Issue: 2
Electronic Location Identifier: 020704
Publisher ID: bm-31-2-020704
DOI: 10.11613/BM.2021.020704
Order of draw of blood samples affect potassium results without K-EDTA contamination during routine workflow
Introduction
A specific sequence is recommended for filling blood tubes during blood collection to prevent erroneous test results due to carryover of additives. However, requirement of this procedure is still debatable. This study was aimed to investigate the potassium ethylenediaminetetraacetic acid (K-EDTA) contamination in blood samples taken after a tube containing the additive during routine workflow. The study was also carried out to examine the effect of order of draw on potassium results, regardless of K-EDTA contamination.
Materials and methods
In 388 outpatients, to determine the probability of K-EDTA cross-contamination, blood was drawn sequentially into a serum tube, followed by a tube containing K-EDTA, and by another serum tube. In another 405 outpatients, to evaluate the effect of order of draw blood unrelated to K-EDTA contamination, two serum tube were successively collected. Potassium was measured on Cobas 6000 c501 analyser (Roche Diagnostic GmbH, Mannheim, Germany) by indirect ion selective electrode method.
Results
Of paired samples collected before and after a K-EDTA tube, 24% had a potassium difference of above 0.3 mmol/L. However, no EDTA contamination was detected in these samples as well as 95% confidence intervals (CI) of limits of agreement for calcium were within the allowable error limits based on reference change values. Interestingly, of blood samples drawn successively, 24% had also a difference greater than 0.3 mmol/L for potassium.