Journal Information
Journal ID (publisher-id): BM
Journal ID (nlm-ta): Biochem Med (Zagreb)
Title: Biochemia Medica
Abbreviated Title: Biochem. Med. (Zagreb)
ISSN (print): 1330-0962
ISSN (electronic): 1846-7482
Publisher: Croatian Society of Medical Biochemistry and Laboratory Medicine
Article Information
Copyright statement: ©Croatian Society of Medical Biochemistry and Laboratory Medicine.
Copyright: 2018, Croatian Society of Medical Biochemistry
License (open-access):
This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Date received: 29 March 2019
Date accepted: 26 June 2019
Publication date (print and electronic): 15 October 2019
Volume: 29
Issue: 3
Electronic Location Identifier: 030705
Publisher ID: bm-29-3-030705
DOI: 10.11613/BM.2019.030705
Effectiveness of minimum retesting intervals in managing repetitive laboratory testing: experience from a Croatian university hospital
Ivana Lapić[*]
Author notes:
[*] Corresponding author: ivana.lapic@hotmail.com
Introduction
Inappropriate laboratory retesting can be addressed by implementing minimum retesting intervals (MRI). The aim of our study was to assess the effectiveness of the implemented MRI protocol for inpatients.
Materials and methods
Minimum retesting intervals were applied for 53 laboratory tests. The overall reduction of test requests, reduction in charges and reagent cost savings, frequency of MRI alert appearance as well as the rate of MRI acceptance and ignorance were calculated for a one-year period. Reasons for violating the MRI rule, hospital departments that contributed mostly to MRI rule violation, and the frequency of MRI violations between routine and emergency laboratory were evaluated.
Results
During the one-year period, 106,780 requests violated the MRI rule, which corresponds to 14.8% of all requests received. 13,843 requests were cancelled, yielding a 1.9% reduction of requested tests. High-volume tests, namely complete blood count, C-reactive protein, alanine aminotransferase, gamma-glutamyltransferase and total bilirubin, accounted for 65% of all generated alerts and had the highest alert ignorance (>85%). The highest cancellation rate was observed for tumor markers and autoimmunity tests, for most being at least 50%. Annual charge reduction was 62,641 EUR while reagent cost savings were 11,408 EUR. Tests performed in the emergency laboratory had a higher alert appearance than the same routine tests. The most common reason for MRI violation was clinical justification based on the patient’s condition. Most frequently ignored MRI alerts were in the intensive care unit.
Keywords: evidence-based practice; clinical laboratory services; pre-analytical phase; cost analysis