Journal Information
Journal ID (publisher-id): BM
Journal ID (nlm-ta): Biochem Med (Zagreb)
Title: Biochemia Medica
Abbreviated Title: Biochem. Med. (Zagreb)
ISSN (print): 1330-0962
ISSN (electronic): 1846-7482
Publisher: Croatian Society of Medical Biochemistry and Laboratory Medicine
Article Information
Copyright statement: Croatian Society of Medical Biochemistry and Laboratory Medicine.
Copyright: 2017, Croatian Society of Medical Biochemistry
License (open-access):
This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Date received: 16 May 2017
Date accepted: 08 October 2017
Publication date (electronic): 24 November 2017
Publication date (print): 15 February 2018
Volume: 28
Issue: 1
Electronic Location Identifier: 010901
Publisher ID: bm-28-1-010901
DOI: 10.11613/BM.2018.010901
Appropriateness of digoxin measurement in hospitalized patients
Seyma Oncu[1]
Ozgur Aslan[2]
Reyhan S Ucku[3]
Author notes:
[*] Corresponding author: ayse.gelal@deu.edu.tr
Introduction
Measurement of serum digoxin concentrations before steady-state is reached results in a falsely low concentration, and may affect treatment safety. We evaluated the proportion of serum digoxin measurements performed before steady-state is reached and the reasons for inappropriate sampling in hospitalized patients.
Materials and methods
Electronic medical records of patients hospitalized between January 2011 and December 2015 treated with oral digoxin, that had more than one digoxin measurement were included. Serum digoxin measurements performed before achievement of pharmacological steady state were considered as inappropriate. The chi-square and chi-square for trend tests were used to analyse the relationship between inappropriate measurements and age, gender, diagnosis, inpatient service, serum digoxin, potassium and creatinine concentrations.
Results
We evaluated 2065 hospital admissions for 1621 patients and 11,407 digoxin measurements. The time between consecutive measurements was 1.9 ± 2.4 days and 97% of all measurements were classified as inappropriate. There was no releationship between patient age, gender, serum creatinine concentration and inappropriate measurement. As opposed to expected, inappropriate digoxin measurement was higher when potassium concentrations were within the normal range (P = 0.025). Share of inappropriate determinations of digoxin was higher when concentrations > 2.6 nmol/L were recorded (P < 0.05). These measurements were requested most often in coronary care unit and cardiology department.
Keywords: digoxin; therapeutic drug monitoring; heart failure; electronic health records